News

Semi-automatic Blow Machine Maintenance And Troubleshooting

Dec 29, 2021 Leave a message

Most machines faulty is caused of careless maintenance or lack of routine checking. Good maintenance is very important in prolonging the life of the machine and avoiding accidents. 

1) Maintenance

A. Drain water divider regularly 

B. Ensure the oil atomizer never lack #20 machine oil. Change once a week is recommended 

C. Check the Limit switch regularly D. Keep the machine clean to prevent damage to the components. 

2) Troubleshooting 

Some solution for machine faulty 

Problem Reason Solution 
Mould clamping not workingElectric magnetic Valve power offCheck circuit and starting switch
Pressure is too lowIncrease cylinder pressure 
Cylinder sealing ring leaksChange sealing rings 
No stretching action or stretches too slowPressure not sufficientIncrease pressure
Cylinder leaksChange sealing rings
No blowing actionBlow valve power not connectedCheck circuit and blow valve
Air pipe damage or connection looseAdjust or change the pipe